10/15
Table 8-1
Machine data overview for SINUMERIK 840D sl, continued
Number
Identifiers
13302
PROFISAFE_IN_ENABLE_MASK
13303
PROFISAFE_OUT_ENABLE_MASK
13304
PROFISAFE_IN_SUBS_ENAB_MASK
13305
PROFISAFE_IN_SUBS
13307
PROFISAFE_IPO_RESERVE
13308
PROFISAFE_IN_NAME
13309
PROFISAFE_OUT_NAME
13310
SAFE_SPL_START_TIMEOUT
13312
SAFE_SPL_USER_DATA
13316
SAFE_GLOB_CONFIG_CHANGE_DATA
13317
SAFE_GLOB_PREV_CONFIG
13318
SAFE_GLOB_ACT_CHECKSUM
13319
SAFE_GLOB_DES_CHECKSUM
13320
SAFE_SRDP_IPO_TIME_RATIO
13322
INFO_SAFE_SRDP_CYCLE_TIME
13330
SAFE_SDP_ENABLE_MASK
13331
SAFE_SDP_ID
13332
SAFE_SDP_NAME
13333
SAFE_SDP_CONNECTION_NR
13334
SAFE_SDP_LADDR
13335
SAFE_SDP_TIMEOUT
13336
SAFE_SDP_ASSIGN
13337
SAFE_SDP_FILTER
13338
SAFE_SDP_ERR_REAC
13340
SAFE_RDP_ENABLE_MASK
13341
SAFE_RDP_ID
13342
SAFE_RDP_NAME
13343
SAFE_RDP_CONNECTION_NR
13344
SAFE_RDP_LADDR
13345
SAFE_RDP_TIMEOUT
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
8.1 Machine data for SINUMERIK 840D sl
Name
Enable screen of the connections to
PROFIsafe input modules
Enable screen form of the connections to
PROFIsafe outputs modules
Activation of the substitute value output for
PROFIsafe input modules
Substitute values for passive connections to
PROFIsafe input modules
Number of IPO clock cycles without
PROFIsafe calculations
Name of the PROFIsafe input module
Name of the PROFIsafe output module
Delay, display Alarm 27097
User SPL data is changed
Date/time of the last change SI- -NCK- -MD
Data, previous safety configuration
Actual checksum NCK
Reference checksum
Factor F_DP communication clock cycle
Maximum F_DP communication clock cycle
Enable screen form F_SENDDP communi-
cation relationships
Identifier of the F_SENDDP communication
relationship
Name of the SPL connection
Number of the SPL connection
Basis address of the input/output data area
F_SENDDP
Monitoring time for F_SENDDP
Output assignment.$A_OUTSE to
F_SENDDP net data
F net data filter between $A_OUTSE and
F_SENDDP
Error response
Enable screen form F_RECVDP communi-
cation relationship
Identifier of the F_RECVDP communication
relationship
Name of the SPL connection
Assignment, SPL connection to system
variables
Basis address of the input/output data area,
F_RECVDP
Monitoring time for F_RECVDP
Data Description
Checksums MD
NCK[2]
NCK[2]
NCK[2]
NCK[0]
- -- -
- -- -
- -- -
NCK[1]
- -- -
- -- -
- -- -
- -- -
NCK[0]
- -- -
NCK[2]
NCK[0]
- -- -
NCK[0]
NCK[0]
NCK[0]
NCK[0]
NCK[0]
NCK[0]
NCK[2]
NCK[0]
- -- -
NCK[0]
NCK[0]
NCK[0]
8-349