10/15
27250
Parameter
Explanation
Response
Remedy
Program
r
continuation
27251
Parameter
Explanation
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
PROFIsafe: Configuration in DP- -M was changed;
%2
=
%1 = NCK project number
%2 = current PLC project number
The DP master indicates a modified S7 PROFIBUS configuration.
Error--free operation can no longer be guaranteed.
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Communication with the F slaves is exited.
A STOP D/E is initiated (this can be set using MD10097
$MN_SAFE_SPL_STOP_MODE) on all axes with safety functionality.
Restart the PLC/NCK
Switch control system OFF and ON again.
PROFIsafe: F module %1, %2 signals an error %3
%1 = PROFIsafe address or name
%2 = signaling components (master/slave)
%3 = error detection
There is a communication error between the F master and the specified
F module.
The component that detected the error is displayed in %2:
-- Master: Error was detected in the F master.
-- Slave: Error was detected in the F slave.
If the alarm was detected in the "F--Slave" then the following error IDs
(%3) are possible:
-- CN: An error was discovered in the telegram sequence.
-- CRC: A CRC error was detected
-- TO: The parameterized communication timeout has been exceeded
or the PROFIsafe address was incorrectly set.
-- LBF: Communication error, telegram mirroring
If the alarm was detected in the "F--master" then the following error IDs
(%3) are possible:
-- CN: An error was detected in the telegram sequence
-- CRC: A CRC error was detected
-- TO: The parameterized communication timeout has been exceeded
-- EA: F slave sends empty telegrams
-- TF: Time overflow
All of the specified values for %3 can, depending on the error profile,
also be displayed in a combination.
10.2NCK safety alarms for Sinumerik 840D sl
Diagnostics
error code %1
10-725