Siemens Sinumerik 840D sl Function Manual page 525

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

10/15
Table 8-8
Overview of DB 18 signals, continued
Signal
CMDSI
PS_FEHL
IBN_FAULT
COMM_TO
STOP_FROM_NC
STATSI
LEVELSI
PLCSIIN[1 ..32]
PLCSIOUT[1 ..32]
SPL_STATUS
F_SENDDP
Inputs
FSDP[1..3].ERR_REAC
FSDP_HF[4..16].ERR_REAC
Outputs
FSDP[1..3].ERROR
FSDP_HF[4..16].ERROR
FSDP[1..3].SUBS_ON
FSDP_HF[4..16].SUBS_ON
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
r/w
Type
Value range
r/w
Bool
r
Bool
r
Bool
r
Bool
r
Bool
r
Dint
r
Dint
r/w
Bool
r
Bool
r
Bool
r/w
Int
0, 1, 2, 3
r
Bool
TRUE,
FALSE
r
Bool
TRUE,
FALSE
Data Description
8.6 Interface signals
Remark
The timeout value in the crosswise
data comparison is extended by a
factor of 10
PS--communication error, in con-
junction with PROFIsafe, an error is
signaled
CDC error "SPL protection status"
(Status NC: $MN_PREVENT_SYN-
ACT_LOCK not equal to PLC:
SPL_READY)
0 --> 1 communications timeout de-
tected, PLC will go to STOP in 5 s
NCK signals a stop to the PLC.
Crosswise data comparison error if
the value is not equal to 0
CDC stack level display
(diagnostics capability: How many
SPL signals currently have different
levels)
Single--channel signals from the
PLC to NCK
Single--channel signals from the
NCK to the PLC
Status signals from NCK to PLC
0 = Alarm27350 + STOP D/E
1 = Alarm 27350
2 = Alarm 27351 (only display, self--
clearing)
3 = No system reaction
0 = Normal mode
1 = Communication error
0 = output of process values
1 = output of substitute values
8-525

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents