10/15
Table 8-8
Overview of DB 18 signals, continued
Signal
FRDP[..3].DIAG
FRDP_HF[4..16].DIAG
FRDP[1..3].RETVAL14
FRDP_HF[4..16].RETVAL14
FRDP[1..3].RETVAL15
FRDP_HF[4..16].RETVAL15
User data
MD13312: $MN_SAFE_SPL_USER_DATA[0]=1h corresponds to DB18.DBX259.0 = 1
MD13312: $MN_SAFE_SPL_USER_DATA[1]=2702h corresponds to
DB18.DBX263.1 = 1
DB18.DBX262.0 = 1
DB18.DBX262.1 = 1
DB18.DBX262.2 = 1
DB18.DBX262.5 = 1
Data area/status
SPL_DATA_HF.INSEP[65...192]
SPL_DATA_HF.OUT-
SEP[65...192]
SPL_DATA_HF.INSIP[65...192]
SPL_DATA_HF.OUT-
SIP[65...192]
SPL_DATA_HF.MARKER-
SIP[65...192]
SPL_DELTA_HF.INSEP[65...192]
SPL_DELTA_HF.OUT-
SEP[65...192]
SPL_DELTA_HF.INSIP[65...192]
SPL_DELTA_HF.OUT-
SIP[65...192]
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
r/w
Type
Value range
r
Word
2#0000_0000_
0000_0000
--
2#1110_0000_0
111_0000
r
Word
r
Word
r
Bool
r/w
Bool
r
Bool
r/w
Bool
r/w
Bool
r
Bool
r/w
Bool
r
Bool
r/w
Bool
Data Description
8.6 Interface signals
Remark
Bit 0--3: Reserved
Bit 4: 1 = Timeout detected
Bit 5: 1 = Sequence number error
detected
Bit 6: 1 = CRC error detected
Bit 7--12: Reserved
Bit 13: 1 = Discrepancies in the F
telegram data (Telegram Discrep-
ancy)
Bit 14: 1 = Sign--of--life monitoring
(LifeSign)
Bit 15: 1 = Asynchronous fault state
(StateFault)
Error code of the SFC 14 (descrip-
tion of the error codes in the online
help for SFC 14)
Error code of the SFC 15 (descrip-
tion of the error codes in the online
help for SFC 15)
External PLC input for the SPL
User data
External PLC input for the SPL
User data
Internal PLC input for the SPL
User data
Internal PLC input for the SPL
User data
Marker for SPL
User data
External PLC input for the SPL
Signal differences for diagnostics
External PLC input for the SPL
Signal differences for diagnostics
Internal PLC input for the SPL
Signal differences for diagnostics
Internal PLC input for the SPL
Signal differences for diagnostics