Siemens Sinumerik 840D sl Function Manual page 348

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Data Description
8.1 Machine data for SINUMERIK 840D sl
Table 8-1
Machine data overview for SINUMERIK 840D sl
Number
Identifiers
General ($MN_ ...)
10050
SYSCLOCK_CYCLE_TIME
10060
POSCTRL_SYSCLOCK_TIME_RATIO
10070
IPO_SYSCLOCK_TIME_RATIO
10071
IPO_CYCLE_TIME
10089
SAFE_PULSE_DIS_TIME_BUSFAIL
10090
SAFETY_SYSCLOCK_TIME_RATIO
10091
INFO_SAFETY_CYCLE_TIME
10092
INFO_CROSSCHECK_CYCLE_TIME
10093
INFO_NUM_SAFE_FILE_ACCESS
10094
SAFE_ALARM_SUPPRESS_LEVEL
10095
SAFE_MODE_MASK, Bit 1
10096
SAFE_DIAGNOSIS_MASK
10097
SAFE_SPL_STOP_MODE
10098
PROFISAFE_IPO_TIME_RATIO
10099
INFO_PROFISAFE_CYCLE_TIME
10200
INT_INCR_PER_MM
10210
INT_INCR_PER_DEG
10385
PROFISAFE_MASTER_ADRESS
10386
PROFISAFE_IN_ADRESS
10387
PROFISAFE_OUT_ADRESS
10388
PROFISAFE_IN_ASSIGN
10389
PROFISAFE_OUT_ASSIGN
10393
SAFE_DRIVE_LOGIC_ADDRESS
11500
PREVENT_SYNACT_LOCK
11602
ASUP_START_MASK
11604
ASUP_START_PRIO_LEVEL
11411
ENABLE_ALARM_MASK
11415
SUPPRESS_ALARM_MASK_2
13300
PROFISAFE_IN_FILTER
13301
PROFISAFE_OUT_FILTER
8-348
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Name
Basic system clock cycle, see /FB1/, G2
Factor, position controller clock cycle,
see /FB1/, G2
Factor, interpolator clock cycle
Interpolator clock cycle
Wait time pulse cancellation when the bus
fails
Factor for monitoring clock cycle
Display, monitoring clock cycle time
Displays the clock cycle time for a cross-
wise data comparison
Number of SPL file access operations
Alarm suppression level
Safety Integrated operating modes
Safety Integrated diagnostic functions
Stop response for SPL errors
Factor PROFIsafe communications clock
cycle time
PROFIsafe communications clock cycle
time
Computational resolution for linear positions
see /FB1/, G2
Computational resolution for angular
positions see /FB1/, G2
PROFIsafe address of the F master
PROFIsafe address of an input module
PROFIsafe address of an output module
Assignment between an ext. SPL interface
$A_INSE and a PROFIsafe input module
Assignment between an ext. SPL interface
$A_OUTSE and a PROFIsafe output
module
Logical drive addresses, SI
Protected synchronized actions
Ignore stop conditions for ASUB
Priorities as of which ASUP_START_MASK
takes effect
Activation of alarms
Suppress alarm outputs
F useful (net) data filter IN
F net (useful) data filter OUT
© Siemens AG 2015 All Rights Reserved
10/15
Checksums MD
- -- -
- -- -
- -- -
NCK[0]
AX[0]
- -- -
AX[0]
- -- -
- -- -
- -- -
NCK[2]
NCK[0]
- -- -
NCK[0]
NCK[0]
- -- -
- -- -
- -- -
NCK[0]
NCK[0]
NCK[0]
NCK[0]
NCK[0]
AX[2]
- -- -
- -- -
- -- -
----
----
NCK[0]
NCK[0]

Advertisement