Data Description
8.7 System variables
Table 8-9
Overview of system variables, continued
Markers and timers
$A_MARKERSI[n]
Marker
$A_MARKER-
Marker
SID[n]
$A_MARKER-
Image of the PLC markers
SIP[n]
$A_MARKER-
Image of the PLC markers
SIPD[n]
$A_TIMERSI[n]
Timer
F_SENDDP
Inputs
$A_FSDP_ERR_R
Response when a communication
EAC[n]
error occurs
Outputs
$A_FSDP_ER-
There is a communication error
ROR[n]
$A_FSDP_SUBS_
Substitute values are output to the
ON[n]
application at the F_RECVDP
(receiver)
$A_FSDP_DIAG[n
The cause of the communication
error determined by F_SENDDP
]
is communicated
8-532
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
n = 1, 2, ... 192
BOOL
stands for the
number of the
1)
marker
n = 1, 2, ... 6
INT
stands for the
number of the
double word
1)
(32 bit)
n = 1, 2, ...192
BOOL
1)
stands for the
number of the
marker
n = 1, 2, ... 6
INT
stands for the
number of the
double word
1)
(32 bit)
n = 1, 2...16
REAL
stands for the
number of the
timer
n = 1, ..., 16
INT
stands for the
number of the
F- -SENDDP
relationship, is
also valid for
$A_FDFSDP_
ERROR;,
$A_FSDP_
SUBS_ON,
$AFSDP_DIAG
n = 1, ..., 16
BOOL
n = 1, ..., 16
BOOL
n = 1, ..., 16
INT
© Siemens AG 2015 All Rights Reserved
10/15
r
w
r
w
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Advertisement