Diagnostics
10.2 NCK safety alarms for Sinumerik 840D sl
Response
Remedy
Program
r
continuation
27305
Parameter
Explanation
Response
Remedy
r
Program
continuation
10-732
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Alarm display
NC start disable in this channel
Interface signals are set
Mode group not ready
Channel not ready
NC stop for alarm
Correct the specified MD
Switch--off – switch--on the control
F_DP: Parameter MD %1[%2] < > MD %3[%4]
%1 = MD name 1
%2 = MD field index for MD name 1
%3 = MD name 2
%4 = MD field index for MD name 2
An SPL connection with several SPL couplings (sub--slots) was para-
meterized, where different values are entered in the F_DP communica-
tion parameters or the connection numbers (%1 and %3).
Note
SPL couplings (sub--slots) of an SPL connection are designated using
the same values for:
-- F_DP communication parameters
-- SPL connection number
The following NCK machine data can be involved:
-- MD13334/13344 $MN_SAFE_SDP/RDP_LADDR or
-- MD13335/13345 $MN_SAFE_SDP/RDP_TIMEOUT or
-- MD13333/13343 $MN_SAFE_SDP/RDP_CONNECTION_NR
-- MD13338/13348 $MN_SAFE_SDP/RDP_ERR_REAC
-- MD13349 $MN_SAFE_RDP_SUBS
Alarm display
NC start disable in this channel
Interface signals are set
Mode group not ready
Channel not ready
Correct the specified MD
Switch--off – switch--on the control
© Siemens AG 2015 All Rights Reserved