Interface Signals - Siemens Sinumerik 840D sl Function Manual

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Data Description

8.6 Interface signals

8.6
Interface signals
General information
The safety--related input and output signals (SGE and SGA) are signals that are
sent to and received from the system through two channels.
Warning
!
A STOP F (displayed using Alarms 27001, 27101 and onwards or F01711) only
results in a subsequent STOP B/A response, if at least one of the safety--related
functions SBH, SG, SE, SN or n<n
the function "n < n
STOP B/A response.
This means that if "n < n
SBH, SG, SE or SN functions must be active or selected (e.g. by selecting a high
SG level).
Note
The SGE/SGA in the drive monitoring channel are mapped in an area of the
NC/PLC interface (signals to/from the drive) and must be supplied in the PLC user
program.
As a result of the two--channel structure of Safety Integrated, the machine
manufacturer must supply the SGE and SGA in both the NCK monitoring channel
and the drive monitoring channel.
Unused SGEs must be set to a defined state.
8-498
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
synchronization is active or selected. If only
x
" is active, then a STOP F does not result in a subsequent
x
" is used as a safety function, then at least one of the
x
© Siemens AG 2015 All Rights Reserved
10/15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents