10/15
p9653
SI Safe Stop 1 drive- -based braking response
Sets the drive- -autonomous braking response for the "Safe Stop 1" (SS1).
Value: 0: SS1 with OFF3
Value 1: SS1E external stop
Note:
SS1: Safe Stop 1 (safe stop 1, corresponds to stop Category 1 according to
EN60204)
SS1E: Safe Stop 1 external (safe stop 1 with external stop)
SS1E requires the externally initiated stop for conformance with stop
Category 1.
This parameter is used to to switch over from SS1 to SS1E and to deactivate
the braking response (drive- -based) of function SS1 (time controlled) of the
Basic Functions.
Unit:
Default value:
0
p9658
SI transition time STOP F to STOP A (Control Unit)
Sets the transition time from STOP F to STOP A on the Control Unit.
See also: r9795, p9858 and F01611
For a crosswise data comparison between p9658 and p9858, a difference of
one safety monitoring clock cycle is tolerated.
The parameterized time is internally rounded- -off to an integer multiple of the
monitoring clock cycle.
STOP F: Defect in a monitoring channel (error in the CDC)
STOP A: Pulse deletion via safety shutdown path
Unit:
Default value:
ms
0
p9659
SI forced checking procedure timer
Sets the time interval to carry out the dynamic update and to test the safety
shutdown paths (forced checking procedure).
Within the parameterized time, STO must have been deselected at least once.
The monitoring time is reset at every STO deselection.
See also: A01699
Unit:
Default value:
h
8
r9660
SI forced checking procedure remaining time
Displays the remaining time until the forced checking procedure and testing the
safety switch- -off signal paths.
See also: A01699
Unit:
Default value:
h
- -
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
Minimum value:
Maximum value:
0
1
Minimum value:
Maximum value:
0
30 000.00
Minimum value:
Maximum value:
0
9 000
Minimum value:
Maximum value:
- -
Data Description
8.2 Parameters for SINAMICS S120
Checksum:
Yes
Data type:
Integer16
Checksum:
Yes
Data type:
Floating Point32
Checksum:
Yes
Data type:
Floating Point32
Checksum:
No
Data type:
Floating Point32
Protection level:
3
Effective:
When exiting the
SI- -commission-
ing mode
Protection level:
3
Effective:
When exiting the
SI- -commission-
ing mode
Protection level:
3
Effective:
When exiting the
SI- -commission-
ing mode
Protection level:
3
Effective:
immediately
8-463