Adjusting Copy Image Area
SP4-010-001 (LE Scan Regist)
5.
Measure the distance between the side edge of the image area and the side edge of the
paper [B].
6.
Adjust the side-to-side registration (SP4-011-001).
SP4-011-001 (S-to-S Scan Regist)
Adjusting Magnification
1.
Place the test chart on the exposure glass. Make sure the test chart is aligned with the rear
and left scales on the exposure glass.
2.
Make a copy.
3.
Compare the copy with the original.
4.
Adjust the main-scan and sub-scan magnifications. The original image [A] is magnified in
the main-scan direction [B] or in the sub-scan direction [C] when you specify a larger value.
The diagrams show the paper on the copy tray. Note that the paper is output with the
face down.
D115/D116
SP
SP
4-64
Specification
0 ± 2 mm
Specification
0 ± 2 mm
SM