SC Tables
No.
Definition
Self-diagnostic error: HDD (Hard Disk Drive)
[XXXX]: Detailed error code
822
When the main switch is turned on or starting the self-diagnostic, the HDD
stays busy for the specified time or more.
[3003]
C
[3004]
C
823
Self-diagnostic Error: NIB
[6101]
C
[6104]
C
[6105]
C
D115/D116
Symptom
Timeout error
Command error
MAC address check sum error
The result of the MAC address
check sum does not match the
check sum stored in ROM.
PHY IC error
The PHY IC on the controller
cannot be correctly recognized.
PHY IC loop-back error
An error occurred during the
loop-back test for the PHY IC on
the controller.
6-20
Possible Cause/Countermeasure
Loose connection
Defective HDD
Defective controller
1.
Check that the HDD is correctly
connected to the controller.
2.
Replace the HDD.
Replace the controller.
Defective controller
1.
Replace the controller.
Same as SC823-[6101]