Hang up setting at DIS reception
disabled
3
0: No hang up
1: Hang up after transmitting DCN
Number of times for training
4
0: 1 time, 1: 2 times
Space CSI transmission setting at
no CSI registration
5
0: Not transmitted,
1: Transmitted
6-7
Not used
IP Fax Switch 08 [SP No. 1-111-009]
No.
FUNCTION
T1 timer adjustment
Adjusts the T1 timer.
The default is "00" (35 seconds).
0-1
Bit 1: 0, Bit 0: 0 = 35 sec
Bit 1: 0, Bit 0: 1 = 40 sec
Bit 1: 1, Bit 0: 0 = 50 sec
Bit 1: 1, Bit 0: 1 = 60 sec
T4 timer adjustment
Adjust the T4 timer.
The default is "00" (3 seconds).
2-3
Bit 3: 0, Bit 2: 0 = 3 sec
Bit 3: 0, Bit 2: 1 = 3.5 sec
Bit 3: 1, Bit 2: 0 = 4 sec
Bit 3: 1, Bit 2: 1 = 5 sec
SM Appendix
Sets whether the machine disconnects after
DIS reception.
Selects the number of times training is done
at the same bit rate.
When "0" is selected, frame data is enabled.
When "1" is selected, the transmitted data is
all spaces.
Do not change these settings.
COMMENTS
-
-