Fusing
4.5.5 THERMOSWITCHES AND THERMISTOR
1.
Hot roller assembly (
2.
Thermoswitches (
3.
Thermistor (
x 1)
Reassembling
Make sure of the following:
That the thermistor is in contact with the hot roller.
That the hot roller turns smoothly.
Do not recycle a thermoswitch that is already opened. Safety is not guaranteed if you
do this.
D115/D116
p.4-17 "Hot Roller and Fusing Lamp")
x 2 for each)
4-18