Address
680549
Country dial wait interval (HIGH)
Time between opening or closing
68054A
the DO relay and opening the
OHDI relay
68054B
Break time for pulse dialing
68054C
Make time for pulse dialing
Time between final OHDI relay
68054D
closure and DO relay opening or
closing
Minimum pause between dialed
68054E
digits (pulse dial mode)
Time waited when a pause is
68054F
entered at the operation panel
680550
DTMF tone on time
680551
DTMF tone off time
Tone attenuation level of DTMF
680552
signals while dialing
Tone attenuation value difference
680553
between high frequency tone and
SM Appendix
Function
1 ms
1 ms
1 ms
1 ms
20 ms
1 ms
-N x 0.5
–3.5 dBm
-dBm x 0.5
5-69
Unit
Remarks
See Notes 3, 6 and 8.
SP2-103-012
(parameter 11).
See Note 3.
SP2-103-013
(parameter 12).
See Note 3.
SP2-103-014
(parameter 13).
See Notes 3, 6 and 8.
SP2-103-015
(parameter 14).
This parameter is only
valid in Europe.
See Note 3 and 8.
SP2-103-016
(parameter 15).
SP2-103-017
(parameter 16). See
Note 3.
SP2-103-018
(parameter 17).
SP2-103-019
(parameter 18).
SP2-103-020
(parameter 19).
See Note 5.
SP2-103-021
(parameter 20).
NCU Parameters