Ricoh Aficio MP201SPF Service Manual page 411

D115/d116
Hide thumbs Also See for Aficio MP201SPF:
Table of Contents

Advertisement

The calling terminal fell
back to T.30 mode,
0-76
because it could not detect
a JM in response to CM
(CM timeout).
The called terminal fell
back to T.30 mode,
0-77
because it could not detect
a CJ in response to JM
(JM timeout).
The called terminal
0-79
detected CI while waiting
for a V.21 signal.
The line was disconnected
0-80
due to a timeout in V.34
phase 2 – line probing.
The line was disconnected
due to a timeout in V.34
0-81
phase 3 – equalizer
training.
The line was disconnected
due to a timeout in the V.34
0-82
phase 4 – control channel
start-up.
The line was disconnected
due to a timeout in the V.34
0-83
control channel restart
sequence.
SM Appendix
The called terminal could not detect a CM due
to noise, etc.
Check the line connection and condition.
Try making a call to another V.8/V.34 fax.
The calling terminal could not detect a JM due
to noise, etc.
A network that has narrow bandwidth cannot
pass JM to the other end.
Check the line connection and condition.
Try receiving a call from another V.8/V.34 fax.
Check for line noise or other line problems.
If this error occurs, the called terminal falls
back to T.30 mode.
The guard timer expired while starting these
phases. Serious noise, narrow bandwidth, or
low signal level can cause these errors.
If these errors happen at the transmitting terminal:
Try making a call at a later time.
Try using V.17 or a slower modem using
dedicated tx parameters.
Try increasing the tx level.
Try adjusting the tx cable equalizer setting.
If these errors happen at the receiving terminal:
Try adjusting the rx cable equalizer setting.
Try increasing the tx level.
Try using V.17 or a slower modem if the same
error is frequent when receiving from multiple
senders.
4-7
Fax Error Codes
D115/D116