6.1.3 GW SC CODE DESCRIPTIONS

SC6xx

No.
Symptom
Definition
MF accounting device error 1
The machine sends a data frame.
632
C
No normal end signal returns.
This symptom happens three
times.
MF accounting device error 2
The machine is communicating
633
C
with the accounting device.
break signal returns.
MF accounting device error 3
634
C
A backup RAM error is reported
from the accounting device.
MF accounting device error 4
635
C
A battery voltage error is reported
from the accounting device.
SM
Possible Cause/Countermeasure
Defective or broken line
between machine and device
Defective or broken line
The
between machine and device
Defective accounting device
controller
Defective battery in the
accounting device
Defective accounting device
controller
Defective battery in the
accounting device