Exceptions; Memory Clear Procedure - Ricoh Aficio MP201SPF Service Manual

D115/d116
Hide thumbs Also See for Aficio MP201SPF:
Table of Contents

Advertisement

Using SP Mode

Exceptions

SP5-998-001 clears most of the settings and counters stored in the NVRAM on the BICU (the
values return to their default values). However, the following settings are not cleared:
SP5-807 (Area Selection)
SP5-811-001 (Serial Num Input [Code Set])
SP5-811-003 (Serial Num Input [ID2 Code Display])
SP5-812-001 (Service TEL [Telephone])
SP5-812-002 (Service TEL [Facsimile])
SP5-907 (Plug & Play)
SP7 (Data Log)
SP8 (History)
Use SP5-998-001 after you have replaced the BICU NVRAM or when the BICU NVRAM data is
corrupted. When the program ends normally, the message "Completed" is displayed. When you
have replaced the controller NVRAM or when the controller NVRAM data is corrupted, use
SP5-801-001. The message is the same as the basic machine.

Memory Clear Procedure

1.
Print out all SMC data lists (
2.
Do SP5-998-001.
3.
Press the OK key.
4.
Select "Execute." The messages "Execute?" followed by "Cancel" and "Execute" are
displayed.
5.
Select "Execute."
6.
When the program has ended normally, the message "Completed" is displayed. If the
program has ended abnormally, an error message is displayed.
7.
Turn the main switch off and on.
8.
Adjust the printer and scanner registration and magnification (* "Copy Adjustment" in the
chapter "Replacement and Adjustment").
9.
Refer to the SMC lists, and enter any values that differ from the factory settings.
Double-check the values for SP4-901.
10. Adjust the standard white level (SP4-428).
11. Initialize the TD sensor (SP 2-214).
12. Check the copy quality and the paper path.
D115/D116
p.5-17 "SMC Print (SP5-990)").
5-16
SM