Sc8Xx - Ricoh Aficio MP201SPF Service Manual

D115/d116
Hide thumbs Also See for Aficio MP201SPF:
Table of Contents

Advertisement

SC Tables

SC8xx

No.
Definition
Monitor Error
817
B
Kernel stop
819
Due to a control error, a RAM overflow occurred during system processing.
One of the following messages was displayed on the operation panel.
[5032]
B
[6261]
B
[0696e]
B
[0766d]
B
[554C]
B
[----]
B
D115/D116
Symptom
This is a file detection and
electronic file signature check
error when the boot loader
attempts to read the
self-diagnostic module, system
kernel, or root system files from
the OS Flash ROM, or the items
on the SD card in the controller
slot are false or corrupted.
HAIC-P2 error
init died
Process error
VM full error
USB error
The others
6-16
Possible Cause/Countermeasure
OS Flash ROM data defective;
change the controller firmware
SD card data defective; use
another SD card
System program defective
Controller board defective
Optional board defective
1.
Replace controller firmware
SM