Fax Error Codes
Communication failed
because of an ID Code
mismatch (Closed
4-10
Network) or Tel. No./CSI
mismatch (Protection
against Wrong
Connections)
5-10
DCR timer expired
Storage impossible
5-20
because of a lack of
memory
5-21
Memory overflow
Print data error when
5-23
printing a substitute rx or
confidential rx message
5-25
SAF file access error
G3 ECM - T1 time out
6-00
during reception of
facsimile data
G3 ECM - no V.21 signal
6-01
was received
G3 ECM - EOR was
6-02
received
G3 ECM - RTC not
6-04
detected
D115/D116
Get the ID Codes the same and/or the CSIs
programmed correctly, then resend.
The machine at the other end may be
defective.
Replace the FCU.
Temporary memory shortage.
Test the SAF memory.
Test the SAF memory.
Ask the other end to resend the message.
Replace an SD card or HDD.
Replace the FCU.
Try adjusting the rx cable equalizer.
Replace the FCU.
Check the line connection.
Check for a bad line or defective remote
terminal.
Replace the FCU.