Since this FC uses unicast meter and broadcast meter, two entries are required to identify these
traffic types explicitly. Another entry is required to classify multicast and unknown-unicast traffic
type to the same FC and use the default meter #11.
FCl1 = 1 + 1 + 1 + 0 = 3
FCaf = 1 + 1 + 1 + 0 = 3
Since this FC uses unicast, broadcast and multicast meter, three entries are required to identify
these traffic types explicitly. Unknown-unicast traffic type is classified using the same entry as
multicast traffic type and uses the same meter.
FCl2 = 0 + 0 + 0 + 0 = 0
FCbe = 1 + 0 + 1 + 0 = 2
Using the above equation, the total classification entries used = 21 and the total meters used = 8
If the same policy were to be used for a SAP in an Epipe service, then since all traffic is classified
to a unicast traffic type and since only unicast meters are used, the following are used:
FCnc = 1 + 0 + 0 + 0 = 1
FCh1 = 1 + 0 + 0 + 0 = 1
FCef = 1 + 0 + 0 + 0 = 1
FCh2 = 1 + 0 + 0 + 0 = 1
FCl1 = 1 + 0 + 0 + 0 = 1
FCaf = 1 + 0 + 0 + 0 = 1
FCl2 = 0 + 0 + 0 + 0 = 0
FCbe = 1 + 0 + 0 + 0 = 1
Using the above equation, the total classification entries used = 7 and the total meters used = 4.
As illustrated in this example, using the same policy for Epipe SAP can lead to inefficient use of
resources. Hence, it is recommended to create a different policy with the required number of
resources (i.e. with
Example 4a (Default multipoint meter "11" is not used):
sap-ingress 10 create
description
num-qos-classifiers
meter 1 create
exit
meter 3 create
exit
meter 2 create
exit
meter 4 create
exit
meter 5 create
exit
7210 SAS D, E, K OS Quality of Service Guide
num-qos-classifiers
"example-policy-3"
20
rate cir 100 pir 100
rate cir
100 pir 100
rate cir 1 pir 20
rate cir 10 pir 100
rate cir 10 pir 10
Service Ingress QoS Policies
= 16)