The number of classification entries (TC) used is calculated, as follows:
(2 * 1)nc + (2 * 1)h1 + (2 * 1)ef + (2 * 1)h2 + (2 * 0)l1 + (2 * 2)af + (2 * 1)l2 + (2 * 1)be = 16
The number of meters (TP) used are: 2 (Meters 1,9 – Note that meters 2 and 12 are not accounted
for, since its not associated with any FC).
7210 SAS D, E, K OS Quality of Service Guide
exit
meter 2 create
exit
meter 9 multipoint create
exit
meter 12 multipoint create
exit
fc "af" create
exit
fc "be" create
exit
fc "ef" create
exit
fc "h1" create
exit
fc "h2" create
exit
fc "l2" create
exit
fc "nc" create
exit
dot1p 1 fc l2 profile in
dot1p 2 fc af profile out
dot1p 3 fc af profile in
dot1p 4 fc h2 profile in
dot1p 5 fc ef profile in
dot1p 6 fc h1 profile in
dot1p 7 fc nc profile in
exit
egress
fc af
exit
fc be
exit
fc ef
exit
fc h1
exit
fc h2
exit
fc l1
exit
fc l2
exit
fc nc
exit
exit