• When you remove the fiber cable from Sensor Controller, make sure to attach the protective cap. If you do not
attach it, it is possible that some contaminants may have adhered and may cause degradation of performance.
• Calibrate the Sensor Head after removing and inserting a fiber cable.
Calibrating Sensor Head p.63
• For checking the fiber is broken, confirm the followings.
Confirm by looking the Sensor head is lighting with connecting to Sensor Controller. To put the diffraction, i.e.. a
paper to around the measurement center of Sensor head, you can confirm by looking.
When the measurement of the high reflection, you may not confirm by looking due to adjustment of intensity
automatically.
• Cleaning the fiber connector and fiber cable using ZW-XCL, follow the procedures.
Cleaning the fiber connector and fiber cable using ZW-XCL
1
Taking out a cleaner
Don't dirty the top of the cleaner, and take one cleaner
from the package.
58
Installation
ZW-7000 User's Manual