4-5 Setting I/O

Settings for Processing When Measrement Is Not Possible

Setting operation when measurement is not possible
Set the output method when the sensor head temporarily enters a non-measurement state, for example, due to
insufficient received light amount or a RESET input state.
Example: When skipping occurs in the measurement values due to low incident level
(1)
(2)
(3)
Direction of
workpiece
movement
Important
When performing hold measurement, the output before the initial hold value is applied is the same as that for "Clamp"
even if "Keep" is set.
Item
Setting item
Non-Measure-
Non-
ment setting
Measurement
setting
1
Set the operating mode to the FUNC mode.
Displacement Sensor ZW-7000 series Confocal Fiber Type Displacement Sensor User's Man-
ual (Z362) "3-3 Switching operation modes"
 Multi View Explore
→ Edit pane
→ I/O Setting Screen
ZW-7000/5000
User's Manual
Amount of displacement
Skipping has occurred due to low
incident level
(2)
(3)
(1)
When [Keep] is selected
Amount of displacement
As the value before skipping occurs is kept, this is
effective in canceling measurement value skipping.
Setting value
Keep
Clamp (default value)
: [Bank Group] | [(Bank Data Name)] (double click)
: [I/O Settings] icon (
: [Non-Measurement Setting]
Description
The measured value before the non-measurement state
was entered is held and output.
With analog output, the preset clamp value (abnormal
value) is output. All judgment outputs become OFF.
)