Adding An Spf Calculation Interval; Deleting An Spf Calculation Interval - Siemens RUGGEDCOM ROX II User Manual

Cli
Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 5
Setup and Configuration
ISTYPE
INTERVAL
------------------------
level-1-only
60
!
!
If no intervals have been configured, add intervals as needed. For more information, refer to
"Adding an SPF Calculation
Section 5.18.8.2

Adding an SPF Calculation Interval

To add an SPF calculation interval to an IS-IS area, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add a new interval by typing:
routing isis area name spf-interval is-type [ level-1-2 | level-1-only | level-2-only ] interval
seconds
Where:
• name is the unique name for a routing process that belongs to a specific router.
• level is the IS type.
• seconds is the minimum interval in seconds, ranging from 1 to 120. The default value is 30.
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
Section 5.18.8.3

Deleting an SPF Calculation Interval

To delete an SPF calculation interval for an IS-IS area, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete the LDP interface by typing:
no routing isis area name spf-interval is-type [ level-1-2 | level-1-only | level-2-only ] interval
seconds
Where:
• name is the unique name for a routing process that belongs to a specific router.
• level is the IS type.
• seconds is the minimum interval in seconds, ranging from 1 to 120. The default value is 30.
Type commit and press Enter to save the changes, or type revert and press Enter to abort.