2.
Configure the IP address range and subnet for the serial terminal or computer's Ethernet port. The range is
typically the IP address for the device's IP interface plus one, ending at *.*.*.254.
By default, the RUGGEDCOM RX1500 has a different IP address and subnet configured for two types of IP
interfaces, both of which are mapped to one or more physical ports:
Port
MGMT
All other Ethernet ports
For example, if the serial terminal or computer is connected to the device's MGMT port, configure the serial
terminal or computer's Ethernet port with an IP address in the range of 192.168.1.3 to 192.168.1.254.
Connect to the device using the IP address 192.168.1.2, the address of the MGMT interface.
3.
Launch the SSH client on the computer and connect to admin@{ipaddress}, where {ipaddress} is the IP
address for the MGMT port. The login prompt appears:
Using username "admin".
admin@192.168.0.2's password:
4.
Log in to RUGGEDCOM ROX II. For more information about logging in to RUGGEDCOM ROX II, refer to
Section 2.3, "Logging
Section 2.1.2

Connecting Through the Network

To connect to RUGGEDCOM ROX II through the network, do the following:
1.
On the workstation being used to connect to the device, configure the Ethernet port to use an IP address
falling within the subnet of the device.
By default, the RUGGEDCOM RX1500 has a different IP address and subnet configured for two types of IP
interfaces, both of which are mapped to one or more physical ports:
Port
MGMT
All other Ethernet ports
For example, if the device is connected via the MGMT port, configure the computer's Ethernet port with
an IP address in the range of 192.168.1.3 to 192.168.1.254. Connect to the device using the IP address
192.168.1.2, the address of the MGMT interface.
2.
Launch the SSH client on the computer and connect to admin@{ipaddress}, where {ipaddress} is the IP
address for the port that is connected to the network.
3.
Log in to RUGGEDCOM ROX II. For more information, refer to
Section 2.2

Default User Names and Passwords

The following default passwords are pre-configured on the device for each access mode:
Connecting Through the Network
In".
IP Address/Mask
192.168.1.2/24
192.168.0.2/24
IP Address/Mask
192.168.1.2/24