  • Page 1 Edition 10/2021 Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX1510 https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Multi Service Platforms RUGGEDCOM RX1510 Modules Technical Specifications Installation Manual Certification 10/2021 C79000-G8976-1055-21...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vii Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................1 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 FCC ........................37 6.1.4 FDA/CDRH ......................37 6.1.5 ISED ........................37 6.1.6 ANATEL ....................... 37 6.1.7 ISO ........................38 6.1.8 RoHS ........................38 6.1.9 Other Approvals ....................38 EMC and Environmental Type Tests ..............39 RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 6: Preface

    Preface This guide describes the RUGGEDCOM RX1510. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device. It is also recommended for use by network and system planners, system programmers, and line technicians.
  • Page 7: Warranty

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Customer Support

    Preface Customer Support Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request to submit a Support Request (SR) or check on the status of an existing SR.
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 10: Introduction

    (EMI) and heavy electrical surges typical of the harsh environments found in many industrial applications. An operating temperature range of -40 to 85 °C (-40 to 185 °F) allows the RUGGEDCOM RX1510 to be placed in almost any location.
  • Page 11 "Connecting to the Device (Page 19)". Utility USB Port Use the USB port to upgrade the RUGGEDCOM RX1510 software or install files, such as configuration files and feature key files. For more information, refer to the "RUGGEDCOM ROX Configuration Manual" for the RUGGEDCOM RX1510.
  • Page 12: Required Tools And Materials

    For more information, refer to "Accessing the CompactFlash Card (Page 21)". Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RX1510: Tools/Materials Purpose AC/DC power cord (16 AWG) For connecting power to the device.
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Installing The Device

    The surface of the device may be hot during operation, or as a result of the ambient air temperature. Wear appropriate personal protective equipment and use caution when working with or around the device. RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 15: General Procedure

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 16: Mounting The Device

    2.3.1 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RX1510 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 17: 2.3.2 Mounting The Device To A Panel

    2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1510 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 18: Connecting The Failsafe Alarm Relay

    NO contact and closes the NC (Normally Closed) contact. Note Control of the failsafe relay output is configurable through RUGGEDCOM RX1510 . One common application for this relay is to signal an alarm if a power failure occurs.
  • Page 19: Connecting Power

    Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RX1510 supports dual redundant high AC, high DC and/or low DC power modules that can be installed in any combination. The use of two power modules is recommended to provide redundancy and load balancing.
  • Page 20: Connecting High Ac/Dc Power

    NOTICE Electrical hazard – risk of damage to equipment Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block. Damage to the power supply may occur. RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 21 AC Terminal Block Wiring – European-style (Euroblock) Terminal Block for HIP Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive/Live (+/L) Terminal Ground Terminal Negative/Neutral (-/N) Terminal Figure 2.5 AC Terminal Block Wiring – Screw Terminal Block for HI Power Supplies RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 22 For screw terminal blocks, install the safety cover. Screw Safety Cover Screw Terminal Block RUGGEDCOM RX1510 Device Figure 2.6 Assembling the Safety Cover Using a braided wire or other appropriate grounding wire, connect the ground terminal to the chassis ground connection.
  • Page 23: 2.5.2 Connecting Low Dc Power

    Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block. Damage to the power supply may occur. Note The RUGGEDCOM RX1510 works with both positive VDC power supplies and negative VDC power supplies. RUGGEDCOM RX1510...
  • Page 24 Ground Terminal Figure 2.8 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for 12P, 24P and 48P Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive (+) Terminal Negative (-) Terminal RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 25 Negative (-) Terminal Ground Terminal Figure 2.10 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for -12P, -24P and -48P Power Supplies Not Connected Removable Screw Terminal Block Non-removable Screw Terminal Block Positive (+) Terminal RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 26 Connect the negative wire from the power source to the negative (-) terminal on the terminal block. For screw terminal blocks, install the safety cover. Screw Safety Cover Screw Terminal Block RUGGEDCOM RX1510 Device Figure 2.12 Assembling the Safety Cover RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 27 #10 Ring Lug #10-32 Screw Connection from External Power Source Ground Connection Figure 2.13 Ground Connection Install the safety cover over the terminal block. This is mandatory for 48 VDC and -48 VDC power supplies. RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 28: Device Management

    This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RX1510 console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM ROX Configuration Manual"...
  • Page 29 Serial Console and Management Ports Connect a workstation directly to the serial console or management ports to access the boot-time control and RUGGEDCOM RX1510 interfaces. The serial console port provides access to RUGGEDCOM RX1510's console interface, while the management port provides access to RUGGEDCOM RX1510's console and Web interfaces.
  • Page 30: Configuring The Device

    Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RX1510 console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RX1510 is https://192.168.0.2. For more information about available ports, refer to "Modules (Page...
  • Page 31 Inserting the CF Card Secure the CF card access panel to the chassis. Removing the CF card To remove the CF card from the device, do the following: Make sure the device is powered down. RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 32 CompactFlash Card Access Panel Figure 3.4 Removing the CF Card Press the ejector button to the left of the CF card and then pull the card out. Secure the CF card access panel to the chassis. RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 33 Device Management 3.3 Accessing the CompactFlash Card RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 34: Modules

    Modules The RUGGEDCOM RX1510 features slots for up to two field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit specific applications. A variety of modules are available, each featuring a specific type of communication port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
  • Page 35: Available Modules

    Modules 4.2 Available Modules Available Modules A variety of modules are available for use with the RUGGEDCOM RX1510. For more information, refer to the "RUGGEDCOM Modules Catalog [https:// support.industry.siemens.com/cs/us/en/view/109747072]" for the RUGGEDCOM RX1510. Installing/Removing Line Modules Upon installing a new line module in the device, all features associated with the module are available in RUGGEDCOM RX1510.
  • Page 36 [Optional] If necessary, install the device in the rack. Installing a Module To install a line module, do the following: [Optional] If the device is installed in a rack, remove it from the rack. Remove the current module from the slot. RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 37: Installing/Removing Power Modules

    Figure 4.3 Installing a Module Tighten the screws to secure the module. [Optional] If necessary, install the device in the rack. Installing/Removing Power Modules The RUGGEDCOM RX1510 supports dual redundant power supply modules. Slot PS1 RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 38 Make sure power to the module is turned off before servicing the power supply terminal. Turn off power to the module. Loosen the screws that secure the module to the chassis until the module can be removed. Chassis Screws Power Supply Figure 4.5 Removing a Power Supply RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 39 Turn on power to the device and confirm the module is receiving and supplying power. This is indicated by the LEDs on the module. State Description Green The module is supplying power Green The module is receiving power RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 40: Technical Specifications

    Rated Switching Current Isolation 30 VDC 2800 VDC for 1 minute 125 VDC 0.1 A , 0.15 A between coil and contacts 250 VAC 6.25 A Inductive load R/L = 7 ms Resistive load RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 41: Operating Environment

    Technical Specifications 5.3 Operating Environment Operating Environment The RUGGEDCOM RX1510 is rated to operate under the following environmental conditions. Note Temperature limits for select line modules may differ from that which can be withstood by the RUGGEDCOM RX1510. Make sure the selected modules are rated for the expected environmental conditions before deployment.
  • Page 42 Technical Specifications 5.5 Dimension Drawings 237.7 Figure 5.1 Overall Dimensions RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 43 Technical Specifications 5.5 Dimension Drawings 286.5 152.4 276.4 78.2 Figure 5.2 Panel and Din Rail Mount Dimensions 162.5 151.4 19.7 Figure 5.3 Line Module Dimensions 162.5 151.8 40.6 Figure 5.4 Power Module Dimensions RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 44: Certification

    Certification The RUGGEDCOM RX1510 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. Note Certifications related to individual modules are detailed in the "RUGGEDCOM Modules Catalog" for the device available online.
  • Page 45 The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd.. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 46: Fcc

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6...
  • Page 47: 6.1.7 Iso

    Quality management systems – Requirements 6.1.8 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 48: Emc And Environmental Type Tests

    Certification 6.2 EMC and Environmental Type Tests EMC and Environmental Type Tests The RUGGEDCOM RX1510 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Test for IEC 61850-3 Test Description Test Levels Severity Levels IEC 61000-4-2 Enclosure Contact ±...
  • Page 49 EMC Immunity Type Tests for IEEE 1613 Note The RUGGEDCOM RX1510 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 50 Long Life (Random Vibration) Category 1 Class B   Shock   IEC 60255-21-3 Seismic Method A Level 2 Military Standard Tests Test Description Test Levels MIL-STD-810G Altitude 12192 m (40000 ft) @ 40 °C, 90 minutes RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 51 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RX1510 Installation Manual, 10/2021, C79000-G8976-1055-21...
  • Page 52 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2021 Siemens Canada Ltd. Subject to change...

Table of Contents