RUGGEDCOM ROX II
CLI User Guide
Parameter
more
nomore
notab
repeat
Using Output Redirects
Description
3:
gmtime "Tue Feb 15 08:37:42 2011\n"
localtime "Tue Feb 15 03:37:42 2011\n"
4:
software-upgrade
.
.
.
Paginates the output. When the output reaches the screen-length
setting, the CLI prompts you to press a key for more. Press Enter to
advance line-by-line; press space to advance page-by-page.
Suppresses pagination.
Suppresses table output.
For example, show chassis | begin line-modules shows the following
table:
ruggedcom# show chassis | begin line-modules
line-modules
line-module
OVERCURRENT
SLOT
DETECTED MODULE
STATUS
----------------------------------------------------------
lm1
1000TX w/ 2x RJ45
lm2
none
lm3
6x RS232/RS422/RS485 via RJ45
lm4
E1 w/ 2x BNC
lm5
none
lm6
none
power-controller
PM
MOV
PM
SLOT
PROTECTION
TEMPERATURE
------------------------------------------------
pm1
na
43
For example, show chassis | begin line-modules | notab suppresses
the table formatting:
ruggedcom# show chassis | begin line-modules |
notab
line-modules
line-module lm1
detected module "1000TX w/ 2x RJ45"
line-module lm2
detected module none
line-module lm3
detected module "6x RS232/RS422/RS485 via
RJ45"
line-module lm4
detected module "E1 w/ 2x BNC"
line-module lm5
detected module none
line-module lm6
detected module none
power-controller
PM
MOV
PM
SLOT
PROTECTION
TEMPERATURE
------------------------------------------------
pm1
na
43
Repeats the term at the specified interval. Specify an interval in
seconds. The term repeats until you cancel it with Ctrl-C.
Chapter 2
Using RUGGEDCOM ROX II
BYPASS
STATUS
-
-
-
-
-
-
-
-
-
-
-
-
PM
PM
CURRENT
VOLTAGE
2907
3381
PM
PM
CURRENT
VOLTAGE
2892
3381
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rx1500Rx1512Rx1501Rx1510Rx1511