11.18
Panel through attachment (MR-J4ACN15K/MR-
J3ACN)
By using the panel through attachment, you can mount the servo amplifier with its heat generation area exposed outside the
cabinet to dissipate the heat, enabling smaller cabinets.
In the cabinet, machine a hole having the panel cut dimensions, fit the panel through attachment to the servo amplifier with the
fitting screws (4 screws supplied), and install the servo amplifier to the cabinet.
Please prepare screws for mounting. They do not come with.
The environment outside the cabinet when using the panel through attachment should be within the range of the servo
amplifier operating environment.
The panel through attachments are used for MR-J4-11KGF(-RJ) to MR-J4-22KGF(-RJ) and MR-J4-11KGF4(-RJ) to MR-J4-
22KGF4(-RJ).
The following shows the combinations.
Servo amplifier
MR-J4-11KGF(-RJ)
MR-J4-15KGF(-RJ)
MR-J4-22KGF(-RJ)
MR-J4-11KGF4(-RJ)
MR-J4-15KGF4(-RJ)
MR-J4-22KGF4(-RJ)
MR-J4ACN15K
■Panel cut dimensions
163
Opening
196
218
■How to assemble the attachment for panel through attachment
Attachment
Screw
(2 places)
11 OPTIONS AND PERIPHERAL EQUIPMENT
442
11.18 Panel through attachment (MR-J4ACN15K/MR-J3ACN)
[Unit: mm]