Mr Configurator2 - Mitsubishi Electric MELSERVO-J4 Series Instruction Manual

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

11.7

MR Configurator2

The MR-J4-_GF_ servo amplifier is supported with software version 1.49B or later.
MR Configurator2 (SW1DNC-MRC2-_) uses the communication function of the servo amplifier to perform parameter setting
changes, graph display, test operation, etc. on a personal computer.
Specifications
Item
Description
Project
Create/read/save/delete project, system setting, and print
Parameter
Parameter setting
Monitor
Display all, I/O monitor, graph, and ABS data display
Diagnosis
Alarm display, alarm onset data, drive recorder, no motor rotation, system configuration, life diagnosis, machine diagnosis, fully
closed loop diagnosis
Test operation
JOG operation
and single-step feed
Adjustment
One-touch tuning, tuning, and machine analyzer
Others
Servo assistant, parameter setting range update, switch display language, and help display
*1 The motor-less operation cannot be used in the fully closed loop control mode, linear servo motor control mode, or DD motor control
mode.
*2 This is available in the standard control mode, fully closed loop control mode, and DD motor control mode.
*3 This is available only in the fully closed loop control mode.
*4 This is available only in the linear servo motor control mode.
*5 This is available only in the I/O mode.
*3
*4
, and linear diagnosis
*2
, positioning operation, motor-less operation
*5
*1
, DO forced output, program operation, test mode information,
11 OPTIONS AND PERIPHERAL EQUIPMENT
11.7 MR Configurator2
11
381