Appendix 11
Connection example
The power circuit is common to all capacity type of servo amplifiers. For the signal and wirings not given in this section, refer
to the following.
Page 84 200 V class
Page 90 400 V class
MCCB
*1
Power supply
Main circuit
power supply
Forced stop 2
*2
Short-circuit connector
(Packed with the servo amplifier)
*1 For the power supply specifications, refer to the following.
Page 30 Servo amplifier standard specifications
*2 This diagram shows sink I/O interface. For source I/O interface, refer to the following.
Page 118 Source I/O interface
*3 Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of contacts) of 80
ms or less. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop
deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn off the
magnetic contactor.
*4 Configure a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the servo amplifier.
*5 When not using the STO function, attach the short-circuit connector came with a servo amplifier.
*6 The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be
configured by one.
*7 Driving the on switch and off switch with the DC power supply meets IEC/EN 60204-1 requirements.
*8 Do not use the 24 V DC interface power supply for the magnetic contactor DC power supply. Always use the power supply designed
exclusively for the magnetic contactor.
*9 If disabling ALM (Malfunction) output with the parameter, configure the power supply circuit which switches off the magnetic contactor
after detection of alarm occurrence on the controller side.
Driving on/off of main circuit power
supply with DC power supply
Malfunction
OFF
RA1
Emergency stop switch
Servo amplifier
24 V DC
*7*8
MC
*3
L1
L2
L3
CN3
*4
EM2
DOCOM
24 V DC
*6
CN8
*5

Appendix 11 Driving on/off of main circuit power supply with DC power supply

MC
ON
MC
SK
CN3
24 V DC
*6
DOCOM
ALM
Malfunction
RA1
*9
*2
A
APPX
625