Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 226

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

No./symbol/
Setting
name
digit
PT57
HMB
Home position
return deceleration
time constant
PT67
VLMT
Speed limit
PT69
ZSTH
Home position shift
distance (extension
parameter)
PT71
DCTH
Travel distance after
proximity dog
(extension
parameter)
5 PARAMETERS
224
5.2 Detailed list of parameters
Function
Set the deceleration time constant at the home position return. Set a deceleration time from the rated speed
to 0 r/min or 0 mm/s.
The parameter will be enabled when you select "Using [Pr. PT56] for acceleration time constant, and [Pr.
PT57] for deceleration time constant (_ _ _ 1)" in [Pr. PT55] Home position return - Deceleration time
constant selection.
Setting range: 0 to 20000
Set a maximum speed for the torque mode.
With equipment for the simple motion connected, writing from MR Configurator2 may not be reflected since
this parameter is updated by the simple motion.
Setting range: 0.00 to instantaneous permissible speed
Set the extension parameter of [Pr. PT07].
When [Pr. PT69] is used, the home position shift distance can be calculated as follows.
Home position shift distance = [Pr. PT07] + ([Pr. PT69]  65536)
This parameter setting is available with servo amplifiers with software version A1 or later.
Setting range: 0 to 32767
Set the extension parameter of [Pr. PT09].
When [Pr. PT71] is used, the travel distance after proximity dog can be calculated as follows.
Travel distance after proximity dog = [Pr. PT09] + ([Pr. PT71]  65536)
This parameter setting is available with servo amplifiers with software version A1 or later.
Setting range: 0 to 32767
Initial
value
[unit]
0 [ms]
500.00
[r/min]/[mm/
s]
0 [pulse]
0 [pulse]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents