digit
PB52
Set the vibration frequency for vibration suppression control 2 to suppress low-frequency machine vibration.
VRF21
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic setting (_ _ 1 _)" in [Pr.
Vibration
PB02], this parameter will be set automatically. "Manual setting (_ _ 2 _)" is selected, the setting written to the
suppression control
parameter is used.
2 - Vibration
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia mode (_ _ _ 1)" in [Pr.
frequency
PA24]. The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a value out of the
range is set, the vibration suppression control is disabled.
Page 254 Advanced vibration suppression control II
Setting range: 0.1 to 300.0
PB53
Set the resonance frequency for vibration suppression control 2 to suppress low-frequency machine
VRF22
vibration.
Vibration
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic setting (_ _ 1 _)" in [Pr.
suppression control
PB02], this parameter will be set automatically. "Manual setting (_ _ 2 _)" is selected, the setting written to the
2 - Resonance
parameter is used.
frequency
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia mode (_ _ _ 1)" in [Pr.
PA24]. The setting range of this parameter varies, depending on the value in [Pr. PB07]. If a value out of the
range is set, the vibration suppression control is disabled.
Page 254 Advanced vibration suppression control II
Setting range: 0.1 to 300.0
PB54
Set a damping of the vibration frequency for vibration suppression control 2 to suppress low-frequency
VRF23
machine vibration.
Vibration
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic setting (_ _ 1 _)" in [Pr.
suppression control
PB02], this parameter will be set automatically. "Manual setting (_ _ 2 _)" is selected, the setting written to the
2 - Vibration
parameter is used.
frequency damping
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia mode (_ _ _ 1)" in [Pr.
PA24]. Page 254 Advanced vibration suppression control II
Setting range: 0.00 to 0.30
PB55
Set a damping of the resonance frequency for vibration suppression control 2 to suppress low-frequency
VRF24
machine vibration.
Vibration
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic setting (_ _ 1 _)" in [Pr.
suppression control
PB02], this parameter will be set automatically. "Manual setting (_ _ 2 _)" is selected, the setting written to the
2 - Resonance
parameter is used.
frequency damping
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia mode (_ _ _ 1)" in [Pr.
PA24]. Page 254 Advanced vibration suppression control II
Setting range: 0.00 to 0.30
PB56
Set the vibration frequency for vibration suppression control 2 for when the gain switching is enabled.
VRF21B
When a value less than 0.1 Hz is set, the value will be the same as that of [Pr. PB52].
Vibration
This parameter will be enabled only when the following conditions are fulfilled.
suppression control
• "Gain adjustment mode selection" is set to "Manual mode (_ _ _ 3)" in [Pr. PA08].
2 - Vibration
• "Vibration suppression mode selection" is set to "3 inertia mode (_ _ _ 1)" in [Pr. PA24].
frequency after gain
• "Vibration suppression control 2 tuning mode selection" is set to "Manual setting (_ _ 2 _)" in [Pr. PB02].
switching
• "Gain switching selection" is set to "Switching is enabled by control command from controller and Input
Switching during driving may cause a shock. Be sure to switch them after the servo motor stops.
Setting range: 0.0 to 300.0
PB57
Set the resonance frequency for vibration suppression control 2 for when the gain switching is enabled.
VRF22B
When a value less than 0.1 Hz is set, the value will be the same as that of [Pr. PB53].
Vibration
This parameter will be enabled only when the following conditions are fulfilled.
suppression control
• "Gain adjustment mode selection" is set to "Manual mode (_ _ _ 3)" in [Pr. PA08].
2 - Resonance
• "Vibration suppression mode selection" is set to "3 inertia mode (_ _ _ 1)" in [Pr. PA24].
frequency after gain
• "Vibration suppression control 2 tuning mode selection" is set to "Manual setting (_ _ 2 _)" in [Pr. PB02].
switching
• "Gain switching selection" is set to "Switching is enabled by control command from controller and Input
Switching during driving may cause a shock. Be sure to switch them after the servo motor stops.
Setting range: 0.0 to 300.0
PB58
Set a damping of the vibration frequency for vibration suppression control 2 when the gain switching is
VRF23B
enabled.
Vibration
This parameter will be enabled only when the following conditions are fulfilled.
suppression control
• "Gain adjustment mode selection" is set to "Manual mode (_ _ _ 3)" in [Pr. PA08].
2 - Vibration
• "Vibration suppression mode selection" is set to "3 inertia mode (_ _ _ 1)" in [Pr. PA24].
frequency damping
• "Vibration suppression control 2 tuning mode selection" is set to "Manual setting (_ _ 2 _)" in [Pr. PB02].
after gain switching
• "Gain switching selection" is set to "Switching is enabled by control command from controller and Input
Switching during driving may cause a shock. Be sure to switch them after the servo motor stops.
Setting range: 0.00 to 0.30
device CDP (Gain switching) (_ _ _ 1)" in [Pr. PB26].
device CDP (Gain switching) (_ _ _ 1)" in [Pr. PB26].
device CDP (Gain switching) (_ _ _ 1)" in [Pr. PB26].
Initial
value
[unit]
100.0 [Hz]
100.0 [Hz]
0.00
0.00
0.0 [Hz]
0.0 [Hz]
0.00