Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 412

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

P P1
W1
W ± 2.5
Servo amplifier
Power factor
improving
DC reactor
MR-J4-200GF4(-RJ)
FR-HEL-H3.7K
MR-J4-350GF4(-RJ)
FR-HEL-H7.5K
MR-J4-500GF4(-RJ)
FR-HEL-H11K
*1 Use this for grounding.
*2 When using the power factor improving DC reactor, remove the short bar between P3 and P4.
*3 Selection conditions of wire size are as follows.
Wire type: 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
11 OPTIONS AND PERIPHERAL EQUIPMENT
410
11.11 Power factor improving DC reactors
4-d mounting hole
*1
D or less
(D3)
D2
D1 ± 1
Dimensions [mm]
W
W1
H
86
55
120
96
60
128
105
75
137
FR-HEL-H
D
D1
D2
D3
95
89
69
45
105
100
80
50
110
105
85
53
Servo amplifier
P3
*2
P4
5 m or less
Terminal
Mass
size
[kg]
d
M4
M4
2.3
M5
M4
3.5
M5
M5
4.5
Wire
2
*3
[mm
]
2 (AWG 14)
2 (AWG 14)
3.5 (AWG 12)