Heat Sink Outside Mounting Attachment (Mr-Acn) - Mitsubishi Electric Melservo-H Series Specifications And Instruction Manual

General-purpose ac servo
Table of Contents

Advertisement

9. OPTIONS AND AUXILIARY EQUIPMENT

9.1.4 Heat sink outside mounting attachment (MR-ACN)

Use the heat sink outside mounting attachment to mount the heat generation area of the servo amplifier
in the outside of the control box to dissipate servo amplifier-generated heat to the outside of the box and
reduce the amount of heat generated in the box, thereby allowing a compact control box to be designed.
In the control box, machine a hole having the panel cut dimensions, fit the heat sink outside mounting
attachment to the servo amplifier with the fitting screws (4 screws supplied), and install the servo
amplifier to the control box.
The environment outside the control box when using the heat sink outside mounting attachment should
be within the range of the servo amplifier operating environment conditions.
(1) Panel cut dimensions
C
A
B
D
(2) Fitting method
Attachment
Attachment supplied to
the servo amplifier(Note)
a. Assembling the heat sink outside mounting attachment
Note: Remove the attachment supplied and fit it in the specified position.
Servo amplifier
4-M10 Screw
Converter unit
MR-HP30KA
MR-H30K
9 - 9
Variable Dimensions
Attachment
A
156
MR-ACNP55K
(6.16)
406
MR-ACN55K
(15.98)
Square
hole
control
box
b. Installation to the control box
[Unit : mm(in)]
B
C
D
110
205
190
(4.33)
(8.09)
(7.48)
360
455
440
(14.17)
(17.91)
(17.32)