Appendix 10
Amplifiers without dynamic brake
Summary
This section explains servo amplifiers without a dynamic brake. The things not explained in this section will be the same as
MR-J4-_GF_(-RJ).
Model
The following describes what each block of a model name indicates. Not all combinations of the symbols are available.
M R - J 4 -
6
0
G F 4
-
Series
Specifications
Dynamic brake which is built in 7 kW or smaller servo amplifiers is removed.
Take safety measures such as making another circuit for an emergency stop, alarm occurrence, and power shut-off.
The following servo motors may function an electronic dynamic brake at an alarm occurrence.
Series
HG-KR
HG-MR
HG-SR
Setting the following parameter disables the electronic dynamic brake.
Servo amplifier
MR-J4-_GF_-ED
MR-J4-_GF_-RU
When [Pr. PA04] is "2 _ _ _" (default), the motor can be a state of forced stop deceleration at an alarm occurrence. Setting "0
_ _ _" in [Pr. PA04] disables the forced stop deceleration function.
Special specification
E
D
Special specifications
Symbol
Special specifications
ED
MR-J4_-GF_ without a dynamic brake
RU
MR-J4-_GF_-RJ without a dynamic brake
Power supply
Symbol
Power supply
None
3-phase 200 V AC to 240 V AC
1
1-phase 100 V AC to 120 V AC
4
3-phase 380 V AC to 480 V AC
Rated output
Symbol Rated output [kW]
10
0.1
20
0.2
40
0.4
60
0.6
70
0.75
100
1
200
2
350
3.5
500
5
700
7
Parameter
[Pr. PF06]
Servo motor
HG-KR053/HG-KR13/HG-KR23/HG-KR43
HG-MR053/HG-MR13/HG-MR23/HG-MR43
HG-SR51/HG-SR52
Setting value
_ _ _ 2
Appendix 10 Special specification
A
APPX
621