11.2

Regenerative options

CAUTION
• Do not use servo amplifiers with regenerative options other than the combinations specified below. Otherwise, it may cause a fire.
Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
200 V class
Servo amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-J4-10GF(-RJ)
MR-J4-20GF(-RJ)
10
MR-J4-40GF(-RJ)
10
MR-J4-60GF(-RJ)
10
MR-J4-70GF(-RJ)
20
MR-J4-100GF(-RJ)
20
MR-J4-200GF(-RJ)
100
MR-J4-350GF(-RJ)
100
MR-J4-500GF(-RJ)
130
MR-J4-700GF(-RJ)
170
Servo amplifier
MR-J4-11KGF(-RJ)
MR-J4-15KGF(-RJ)
MR-J4-22KGF(-RJ)
*1 Always install a cooling fan.
*2 Values in parentheses assume the installation of a cooling fan.
MR-
MR-RB12
MR-RB30
[40 ]
[13 ]
RB032
[40 ]
30
30
100
30
100
30
100
30
100
30
100
300
Regenerative power [W]
External regenerative resistor
(accessory)
500 (800)
850 (1300)
850 (1300)
MR-
MR-RB31
MR-RB32
[6.7 ]
[40 ]
RB3N [9
]
300
300
300
300
300
*2
MR-RB5R [3.2 ] MR-RB9F [3 ]
500 (800)
850 (1300)
11 OPTIONS AND PERIPHERAL EQUIPMENT
MR-RB50
MR-
MR-RB51
*1
*1
[13 ]
[6.7 ]
RB5N [9
*1
]
500
500
500
500
MR-RB9T [2.5 ]
850 (1300)
335
11.2 Regenerative options