Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 503

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

■Magnetic pole detection by the minute position detection method
Magnetic pole detection
1)
Check that LSP (Forward rotation stroke end), LSN (Reverse rotation stroke end), and EM2 (Forced
stop 2) are on, and turn the servo amplifier power off and on again.
2)
Turn "On (up)" the test operation select switch (SW1-1) of the servo amplifier, and then cycle the
power of the servo amplifier.
3)
Set [Pr. PL08 Linear servo motor/DD motor function selection 3] to "_ _ _ 4" to set the magnetic pole
detection method to "Minute position detection method".
4)
Set [Pr. PL01 Linear servo motor/DD motor function selection 1] to "_ _ _ 1" to set "Magnetic pole
detection always enabled".
5)
Turn the servo amplifier power off and on again.
6)
Set the load inertia moment ratio of the direct drive motor with [Pr. PL17 Magnetic pole detection -
Minute position detection method - Function selection].
7)
Execute "Forward CCW rotation" or "Reverse rotation" with "Positioning CW operation" in the test
operation mode on MR Configurator2. Set the travel distance to "0" at this time.
The magnetic pole detection is carried out.
Is the response of the
YES
minute position detection method
set by [Pr. PL17] finalized?
NO
Has an abnormal sound or
vibration occurred during the
magnetic pole detection?
NO
Is the travel distance
during the magnetic pole
detection acceptable?
Acceptable
8)
Set [Pr. PL01] to "_ _ _ 0" to set "Magnetic pole detection disabled".
End
*1 For the incremental system, the [Pr. PL01] setting is not required.
*2 If the load to direct drive motor inertia ratio is unknown, perform the magnetic pole detection by the position detection method, and then
perform the auto tuning to set an estimated value.
*3 For the magnetic pole detection by the minute position detection method, the maximum rotation angle at the magnetic pole detection
must be five degrees or less. To shorten the travel distance, increase the response by the minute position detection method in [Pr.
PL17].
*1
*2
Decrease the response by the minute
YES
position detection method of [Pr. PL17] by
two as the final setting value.
Not
Increase the response by the minute
acceptable
position detection method of [Pr. PL17] by
*3
one.
*1
15 USING A DIRECT DRIVE MOTOR
15.3 Operation and functions
15
501

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents