No.
Name
27
Initial magnetic pole detection
error
28
Linear encoder error 2
2A
Linear encoder error 1
2B
Encoder counter error
30
Regenerative error
31
Overspeed
32
Overcurrent
33
Overvoltage
34
SSCNET receive error 1
35
Command frequency error
36
SSCNET receive error 2
37
Parameter error
39
Program error
Detail
Detail name
No.
27.1
Initial magnetic pole detection - Abnormal termination
27.2
Initial magnetic pole detection - Time out error
27.3
Initial magnetic pole detection - Limit switch error
27.4
Initial magnetic pole detection - Estimated error
27.5
Initial magnetic pole detection - Position deviation
error
27.6
Initial magnetic pole detection - Speed deviation error
27.7
Initial magnetic pole detection - Current error
28.1
Linear encoder - Environment error
2A.1
Linear encoder error 1-1
2A.2
Linear encoder error 1-2
2A.3
Linear encoder error 1-3
2A.4
Linear encoder error 1-4
2A.5
Linear encoder error 1-5
2A.6
Linear encoder error 1-6
2A.7
Linear encoder error 1-7
2A.8
Linear encoder error 1-8
2B.1
Encoder counter error 1
2B.2
Encoder counter error 2
30.1
Regeneration heat error
30.2
Regeneration signal error
30.3
Regeneration feedback signal error
31.1
Abnormal motor speed
32.1
Overcurrent detected at hardware detection circuit
(during operation)
32.2
Overcurrent detected at software detection function
(during operation)
32.3
Overcurrent detected at hardware detection circuit
(during a stop)
32.4
Overcurrent detected at software detection function
(during a stop)
33.1
Main circuit voltage error
34.1
SSCNET receive data error
34.2
SSCNET connector connection error
34.3
SSCNET communication data error
34.4
Hardware error signal detection
34.5
SSCNET receive data error (safety observation
function)
34.6
SSCNET communication data error (safety
observation function)
35.1
Command frequency error
36.1
Continuous communication data error
36.2
Continuous communication data error (safety
observation function)
37.1
Parameter setting range error
37.2
Parameter combination error
37.3
Point table setting error
39.1
Program error
39.2
Instruction argument external error
39.3
Register No. error
39.4
Non-correspondence instruction error
Stop
Alarm deactivation
method
Alarm
CPU
*2*3
reset
reset
DB
DB
DB
DB
DB
DB
DB
EDB
EDB
EDB
EDB
EDB
EDB
EDB
EDB
EDB
EDB
EDB
*1
*1
DB
*1
*1
DB
*1
*1
DB
SD
DB
DB
DB
DB
EDB
*8
*5
SD
*8
SD
*8
SD
*8
SD
*8
SD
*8
SD
SD
*8
SD
*8
SD
DB
DB
DB
DB
DB
DB
DB
8 TROUBLESHOOTING
8.2 Alarm list
Cycling
the
power
*1
*1
8
*1
283

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents