Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 370

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

■400 V class
MCCB
Power
supply
*5
Step-down
transformer
*1 When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain removed, the FR-RC-
H will not operate.
*2 For the servo amplifier of 5 kW and 7 kW, be sure to disconnect the lead wire of built-in regenerative resistor, which is connected to P+
and C terminals. For the servo amplifier of 11 kW to 22 kW, do not connect a supplied regenerative resistor to the P+ and C terminals.
*3 If disabling ALM (Malfunction) output with the parameter, configure up the power supply circuit which switches off the magnetic contactor
after detection of alarm occurrence on the controller side.
*4 Between P3 and P4 is connected by default. When using the power factor improving DC reactor, remove the short bar between P3 and
P4. Additionally, a power factor improving DC reactor and power factor improving AC reactor cannot be used simultaneously.
Page 407 Power factor improving DC reactors
*5 For the power supply specifications, refer to the following.
Page 30 Servo amplifier standard specifications
*6 Set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop 1). Configure up the circuit which shuts off main circuit power with external circuit
at EM1 (Forced stop 1) off.
*7 When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker.
*8 This diagram shows sink I/O interface. For source I/O interface, refer to the following.
Page 118 Source I/O interface
*9 The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be
configured by one.
*10 For selection of power factor improving AC reactors, refer to "Power Regeneration Converter FR-RC Instruction Manual (IB(NA)66330)".
11 OPTIONS AND PERIPHERAL EQUIPMENT
368
11.4 FR-RC-(H) power regeneration converter
*7
Power factor
improving AC reactor
*10
MC
FR-RC-H
B
C
Forced stop 1
*6
*8
*9
24 V DC
RD
Lady
SE
R/L1
S/L2
T/L3
RX
R
SX
S
TX
T
Power regeneration converter
FR-RC-H
Operation
ALM
ready
RA
OFF
Forced stop 1
*6
Servo amplifier
L11
L21
L1
L2
L3
CN3
CN3 24 V DC
EM1
DOCOM
ALM
DICOM
RA
*2
P3 P4
N-
C
P+
5 m or shorter
*4
N/-
P/+
A
B
RDY output
C
Alarm output
Phase detection
*1
terminals
ON
MC
MC
SK
*9
Malfunction
*3
*8
B
C