Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 570

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

For control circuit power supply
When the wiring for the control circuit power supply (L11/L21) is thinner than that for the main circuit power supply (L1/L2/L3/
N-), install an overcurrent protection device (fuse, etc.) to protect the branch circuit.
Servo amplifier
MR-J4-10GF-RJ
MR-J4-20GF-RJ
MR-J4-40GF-RJ
MR-J4-60GF-RJ
MR-J4-70GF-RJ
MR-J4-100GF-RJ
MR-J4-200GF-RJ
MR-J4-350GF-RJ
MR-J4-500GF-RJ
MR-J4-700GF-RJ
MR-J4-11KGF-RJ
MR-J4-15KGF-RJ
MR-J4-22KGF-RJ
APPX
568
Appendix 1 When using the servo amplifier with the DC power supply input
Fuse (Class T)
Current [A]
Voltage DC [V]
1
400
Fuse (Class K5)
Current [A]
Voltage DC [V]
1
400

Hide quick links: