8.2

Alarm list

No.
Name
10
Undervoltage
11
Switch setting error
12
Memory error 1 (RAM)
13
Clock error
14
Control process error
15
Memory error 2
(EEP-ROM)
16
Encoder initial communication
error 1
Detail
Detail name
No.
10.1
Voltage drop in the control circuit power
10.2
Voltage drop in the main circuit power
11.1
Axis number setting error/Station number setting error
11.2
Disabling control axis setting error
12.1
RAM error 1
12.2
RAM error 2
12.3
RAM error 3
12.4
RAM error 4
12.5
RAM error 5
12.6
RAM error 6
13.1
Clock error 1
13.2
Clock error 2
13.3
Clock error 3
14.1
Control process error 1
14.2
Control process error 2
14.3
Control process error 3
14.4
Control process error 4
14.5
Control process error 5
14.6
Control process error 6
14.7
Control process error 7
14.8
Control process error 8
14.9
Control process error 9
14.A
Control process error 10
14.B
Control process error 11
14.C
Control process error 12
14.D
Control process error 13
15.1
EEP-ROM error at power on
15.2
EEP-ROM error during operation
15.4
Home position information read error
16.1
Encoder initial communication - Receive data error 1
16.2
Encoder initial communication - Receive data error 2
16.3
Encoder initial communication - Receive data error 3
16.4
Encoder initial communication - Encoder
*6
malfunction
16.5
Encoder initial communication - Transmission data
error 1
16.6
Encoder initial communication - Transmission data
error 2
16.7
Encoder initial communication - Transmission data
error 3
16.8
Encoder initial communication - Incompatible
*6
encoder
16.A
Encoder initial communication - Process error 1
16.B
Encoder initial communication - Process error 2
16.C
Encoder initial communication - Process error 3
16.D
Encoder initial communication - Process error 4
16.E
Encoder initial communication - Process error 5
16.F
Encoder initial communication - Process error 6
Stop
Alarm deactivation
method
Alarm
CPU
*2*3
reset
reset
EDB
SD
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
DB
8 TROUBLESHOOTING
8.2 Alarm list
Cycling
the
power
8
281

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents