14.4
Characteristics
Overload protection characteristics
An electronic thermal is built in the servo amplifier to protect the linear servo motor, servo amplifier and linear servo motor
power wires from overloads.
[AL. 50 Overload 1] occurs if overload operation performed is above the electronic thermal protection curve shown in the
following figures. [AL. 51 Overload 2] occurs if the maximum current is applied continuously for several seconds due to
machine collision, etc. Use the equipment on the left-side area of the continuous or broken line in the graph.
Use the linear servo motor with 70% or less of the effective load ratio when it is in the servo lock state or in a small
reciprocating motion.
This servo amplifier has linear servo motor overload protection. (The linear servo motor overload current (full load current) is
set on the basis of 120% rated current of the servo amplifier.)
1000
100
10
Servo-lock
1
0.1
0
50
100
Load ratio [%]
a. LM-H3 series
1000
100
10
Servo-lock
1
0.1
0
100
200
Load ratio [%]
c. LM-F series (natural cooling)
Operating
150
200
250
300
LM-K2 series
Operating
300
400
500
600
1000
100
10
Servo-lock
1
0.1
0
100
Load ratio [%]
b. LM-U2 series
1000
100
10
Servo-lock
1
0.1
0
50
100
Load ratio [%]
d. LM-F series (liquid cooling)
14 USING A LINEAR SERVO MOTOR
Operating
200
300
400
Operating
150
200
250
300
14.4 Characteristics
14
489