Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 547

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

■Details of Touch probe function (60B8h)
Bit
Definition
0
0: Touch probe 1 disabled
1: Touch probe 1 enabled
1
0: Single trigger mode
1: Continuous trigger mode
2
0: Set input of touch probe 1 as a trigger
1: Set 0 point of the encoder as a trigger (Unsupported)
3
(reserved) The value at reading is undefined. Set "0" when writing.
4
0: Stop sampling at the rising edge of touch probe 1
1: Start sampling at the rising edge of touch probe 1
5
0: Stop sampling at the falling edge of touch probe 1
1: Start sampling at the falling edge of touch probe 1
6
(reserved) The value at reading is undefined. Set "0" when writing.
7
8
0: Touch probe 2 disabled
1: Touch probe 2 enabled
9
0: Single trigger mode
1: Continuous trigger mode
10
0: Set input of touch probe 2 as a trigger
1: Set 0 point of the encoder as a trigger (Unsupported)
11
(reserved) The value at reading is undefined. Set "0" when writing.
12
0: Stop sampling at the rising edge of touch probe 2
1: Start sampling at the rising edge of touch probe 2
13
0: Stop sampling at the falling edge of touch probe 2
1: Start sampling at the falling edge of touch probe 2
14
(reserved) The value at reading is undefined. Set "0" when writing.
15
*1 This is not available with MR-J4-_GF_ servo amplifier.
■Details of Touch probe status (60B9h)
Bit
Definition
0
0: Touch probe 1 disabled
1: Touch probe 1 enabled
1
0: The rising edge position of touch probe 1 has not been stored.
1: The rising edge position of touch probe 1 has been stored.
2
0: The falling edge position of touch probe 1 has not been stored.
1: The falling edge position of touch probe 1 has been stored.
3
(reserved) The value at reading is undefined.
4
5
6
7
8
0: Touch probe 2 disabled
1: Touch probe 2 enabled
9
0: The rising edge position of touch probe 2 has not been stored.
1: The rising edge position of touch probe 2 has been stored.
10
0: The falling edge position of touch probe 2 has not been stored.
1: The falling edge position of touch probe 2 has been stored.
11
(reserved) The value at reading is undefined.
12
13
14
15
*1
*1
17 APPLICATION OF FUNCTIONS
17.2 Touch probe
17
545