Mitsubishi Electric MELSERVO-J4 Series Instruction Manual page 197

Cc-link ie field network interface servo amplifier instruction manual (motion mode)
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

No./symbol/
Setting
Function
name
digit
PB17
Set the shaft resonance suppression filter.
NHF
Use this to suppress a high-frequency machine vibration.
Shaft resonance
When you select "Automatic setting (_ _ _ 0)" of "Shaft resonance suppression filter selection" in [Pr. PB23], the value will be calculated
suppression filter
automatically from the servo motor you use and load to motor inertia ratio. It will not be automatically calculated for the linear servo
motor. When "Manual setting (_ _ _ 1)" is selected, the setting written to the parameter is used.
When "Shaft resonance suppression filter selection" is set to "Disabled (_ _ _ 2)" in [Pr. PB23], the setting value of this parameter will be
disabled.
When "Machine resonance suppression filter 4 selection" is set to "Enabled (_ _ _ 1)" in [Pr. PB49], the shaft resonance suppression
filter is not available.
When "Shaft resonance suppression filter selection" is set to "Disabled (_ _ _ 2)" in [Pr. PB23], the performance may be reduced.
_ _ x x
Shaft resonance suppression filter setting frequency selection
Refer to the following table for settings.
Set the value closest to the frequency you need.
_ x _ _
Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
x _ _ _
For manufacturer setting
Setting value
_ _ 0 0
_ _ 0 1
_ _ 0 2
_ _ 0 3
_ _ 0 4
_ _ 0 5
_ _ 0 6
_ _ 0 7
_ _ 0 8
_ _ 0 9
_ _ 0 A
_ _ 0 B
_ _ 0 C
_ _ 0 D
_ _ 0 E
_ _ 0 F
PB18
Set the low-pass filter.
LPF
Refer to the following table for the relation of setting values for the related parameter to the status of this
Low-pass filter
parameter.
setting
Setting range: 100 to 18000
[Pr. PB23]
_ _ 0 _ (Initial value)
_ _ 1 _
_ _ 2 _
PB19
Set the vibration frequency for vibration suppression control 1 to suppress low-frequency machine vibration.
VRF11
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic setting (_ _ _ 1)" in [Pr.
Vibration
PB02], this parameter will be set automatically. When "Manual setting (_ _ _ 2)" is selected, the setting written
suppression control
to the parameter is used. The setting range of this parameter varies, depending on the value in [Pr. PB07]. If
1 - Vibration
a value out of the range is set, the vibration suppression control is disabled.
Page 254 Advanced vibration suppression control II
frequency
Setting range: 0.1 to 300.0
Frequency [Hz]
Setting value
Disabled
_ _ 1 0
Disabled
_ _ 1 1
4500
_ _ 1 2
3000
_ _ 1 3
2250
_ _ 1 4
1800
_ _ 1 5
1500
_ _ 1 6
1285
_ _ 1 7
1125
_ _ 1 8
1000
_ _ 1 9
900
_ _ 1 A
_ _ 1 B
818
750
_ _ 1 C
692
_ _ 1 D
642
_ _ 1 E
600
_ _ 1 F
[Pr. PB18]
Automatic setting
Setting value enabled
Setting value disabled
Initial
value
[unit]
00h
0h
0h
Frequency [Hz]
562
529
500
473
450
428
409
391
375
360
346
333
321
310
300
290
3141
[rad/s]
100.0 [Hz]
5 PARAMETERS
5.2 Detailed list of parameters
5