Duplicate Setting; Duplication Using Mr Configurator2; Test Operation; Execution Method - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

4.4

Duplicate setting

Servo amplifier parameters for which setting has been completed can be copied to another servo amplifier. Use this function
when replacing the servo amplifier of equipment with another servo amplifier during operation, and when starting up multiple
devices with the same configuration.
Restrictions
■The following data are not duplicated. Set them as required after the duplication.
Item
Homing
Machine service life diagnosis
■The following data are not duplicated.
• Alarm history data
• Drive recorder data

Duplication using MR Configurator2

1.
The data set in MR Configurator2 can be saved as a project.
2.
To copy the project to a different servo amplifier, open the project and then connect the servo amplifier and a personal
computer via a USB cable. Switch on control circuit power supply of the servo amplifier.
3.
Write the required data in MR Configurator2. After the writing is completed, cycle the power or reset the software, as
necessary.
4.5

Test operation

Using the test operation function enables the machine operation to be checked before the actual operation. With a personal
computer and MR Configurator2, operations such as the JOG operation, positioning operation, output signal forced output,
and program operation can be used.
Precautions
• The test operation mode is designed for checking servo operation. This mode is not for checking machine operation. Do not
use this mode with the machine. Use this mode only with the servo motor.

Execution method

Test operation mode is enabled by MR Configurator2. To set to the normal operation mode again after executing the test
operation mode, cycle the power or reset the software.
• Perform the test operation after the forced stop has been released. For details of the forced stop, refer to "Forced stop
deceleration function" in the following manual.
MR-J5 User's Manual (Function)
Description
The information of the home position is not duplicated. Execute homing again.
Machine service life diagnosis information may not be duplicated. Refer to
"Machine diagnosis" in the following manual, and perform required settings.
MR-J5 User's Manual (Function)
4 STARTUP
47
4.4 Duplicate setting
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5-g-n1Melservo-j5w-g-n1

Table of Contents