Siemens SINAMICS G120 Operating Instructions Manual page 443

Low voltage inverters built-in units with cu250s-2 control units and encoder evaluation
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Feature
Encoder input
Temperature sensor
Failsafe digital input
for enabled Basic Functions
PFH
USB interface
Dimensions (WxHxD)
Weight
Memory cards
Operating temperature
Storage temperature
Relative humidity
Converter with the CU250S-2 Control Units
Operating Instructions, 04/2018, FW V4.7 SP10, A5E31759476B AG
Data
HTL, TTL
SSI
Resolver
PTC
KTY84
Pt1000
Temperature switch with NC contact
1 (DI 4 and DI 5)
You can find the failsafe inputs of the Extended safety functions in the "Safety Integra‐
ted" function manual.
Overview of the manuals (Page 519)
5 × 10E-8
Mini-B
73 mm × 199 mm × 63
mm
0.49 kg
Slot for SD or MMC memory cards
Memory cards (Page 362)
-10° C ... 50° C
0 °C ... 50 °C
Observe any possible restrictions regarding the operating temperature as a result of
the Power Module.
- 40° C ... 70° C
< 95%
10.1 Technical data, CU250S-2 Control Unit
Input frequency: ≤ 500 kHz
Baud rate: ≤ 1 MHz
The dependency on baud rate and cable length is shown
in the diagram below.
● Ratio ü = 0.3 ... 0.7
Resolvers with ratios ü < 0.3 or ü > 0.7 reduce the
accuracy of the speed sensing and the resolution of the
position actual value.
● Excitation voltage for ü = 0.5: 1.8 V
● Excitation frequency, synchronized to the current
controller clock cycle: 8 kHz
The impedances that can be connected and the maximum
speed that can be evaluated are listed below.
● Short-circuit monitoring < 20 Ω
● Overtemperature 1650 Ω
● Short-circuit monitoring < 50 Ω
● Wire-break: > 2120 Ω
● Short-circuit monitoring < 603 Ω
● Wire-break > 2120 Ω
● Maximum input voltage: 30 V, 5.5 mA
● Response time:
Typical: 5 ms + debounce time p9651
Typical, if debounce time = 0: 6 ms
Worst-case scenario: 15 ms + debounce time
Worst case, if debounce time = 0: 16 ms
Probability of failure of the safety functions (probability of
failure per hour – PFH)
The depth specification is valid when mounting on the Pow‐
er Module.
Without inserted Operator Panel
With inserted BOP‑2 or IOP-2 operator panel
Condensation is not permissible.
Technical data
rms
441