Installing
4.5 Connecting the interfaces for the inverter control
4.5.6
Default setting of the interfaces
Changing the function of the terminals
The function of the terminals and fieldbus interface can be adjusted.
In order that you do not have to successively change terminal for terminal, several terminals
can be jointly set using default settings ("p0015 Macro drive unit").
The terminal settings made in the factory described above correspond to the following default
settings:
● Default setting 12 (p0015 = 12): "Standard I/O with analog setpoint"
● Default setting 7 (p0015 = 7): "Fieldbus with data set switchover"
Default setting 1: "Conveyor technology with 2 fixed frequencies"
DO 0: p0730, DO 1: p0731
Fixed speed setpoint 3: p1003, fixed speed setpoint 4: p1004, fixed speed setpoint active: r1024
Speed setpoint (main setpoint): p1070[0] = 1024
DI 4 and DI 5 = high: The inverter adds both fixed speed setpoints
Designation in the BOP-2: coN 2 SP
98
AO 0: p0771[0], AO 1: p0771[1]
Operating Instructions, 04/2018, FW V4.7 SP10, A5E31759476B AG
DI 0: r0722.0, ..., DI 5: r0722.5
Converter with the CU250S-2 Control Units