Parameter
p3340[0 ... n]
p3342[0 ... n]
p3343[0 ... n]
r3344
Converter with the CU250S-2 Control Units
Operating Instructions, 04/2018, FW V4.7 SP10, A5E31759476B AG
Explanation
Start limit switch
Minus limit switch
Plus limit switch
Limit switch ON/OFF
.00
1 signal: Limit switch ON
0 signal: Limit switch OFF1
.01
1 signal: Limit switch no OFF3
0 signal: Limit switch OFF3
.02
1 signal: Limit switch, axis stationary (standstill)
.04
1 signal: Plus limit switch actuated
.05
1 signal: Minus limit switch actuated
1 signal: Start is active
0 signal: Start is inactive
1 signal: Limit switch is inactive
0 signal: Limit switch is active
Advanced commissioning
6.11 Limit position control
217