Installing
4.5 Connecting the interfaces for the inverter control
Setting the bus address
Procedure
1. Set the address using one of the subsequently listed options:
– Via the address switch
– On an operator panel via p0918
– With Startdrive
2. Switch off the inverter power supply.
3. Wait until all LEDs on the inverter are dark.
4. Switch on the inverter power supply again.
Your settings become effective after switching on.
The PROFIBUS address is set.
120
Overview of the interfaces on the front and upper side. (Page 92)
Confirm the prompt for saving your settings (copy RAM to ROM).
Converter with the CU250S-2 Control Units
Operating Instructions, 04/2018, FW V4.7 SP10, A5E31759476B AG