Click Apply to implement changes made. The port status of all PoE configured ports is displayed in the table in the
bottom half of the screen shown above.
NOTE: If the switch fails to supply power to the Powered Device (PD) that supports the IEEE 802.3at
standard, try the following steps:
1. Check if the PD connected to the port supports the IEEE 802.3at standard.
2. Manually configure the corresponding port's power limit value to 30 Watts.

PD Alive Settings

This window is used to configure the PD alive check function.
To view the following window, click System Configuration > PoE > PD Alive Settings as shown below:
The following parameters can be configured:
Parameter
From Port / To Port
PD Alive State
PD IP Address
Poll Interval (10-300
sec)
Retry Count (0-5)
Waiting Time (30-
300 sec)
Action
DGS-3000 Series Gigabit Ethernet Switch Web UI Reference Guide
Class 0 – 16200mW
Class 1 – 4200mW
Class 2 – 7400mW
Class 3 – 16200mW
User Define – 1000 to 35000mW
Figure 2-18 PD Alive Settings
Description
Select a range of ports from the drop-down menus.
Use the drop-down menu to enable or disable the PD alive check function.
Enter the IP address of the target PD for the Switch executing the ping action.
Enter the interval for the system to issue ping requests to detect the target PD.
Enter the retry counts of ping requests when PD has no response.
Enter the waiting time for PD to recover from rebooting.
Select the action of the system when PD does not reply the ping request. Options to